Kind of pressure overpressure, relative Pressure connection internal thread G1/4, external thread G1/2 Electrical connection terminal connection M16x1,5 Protection class IP65 Housing material rugged housing of seawater resistant aluminium die casting GD Al Si 12 Sensing element material 1.4104 + 1.4571 Media temp. -15 ... 60 oC Media temp. limit temperatures up to 80 oC are allowable for short periods. Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters) Ambient temperature -15 ... 60 oC Ambient temp. limit at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device Switch function/capacity SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive Certificates • NG-4346 AP 1011 according DIN EN 1854 • CE-0085 AQ 1088 according EU/2009/142/EG (30.11.2009) and DIN EN 1854 (01.07.2006) • PTB 02 ATEX 1121 according Directive 94/9 EC • SIL2 according IEC 61508 Max. pressure 5 bar
|